Heat Pump Hot Water System Manufacturer :: Heat Pump Water Heater System Supplier
 
 
     
  COMPARISON  
 
   
 
 
Comparison 1.        The SEERS Hybrid Hot Water System
 

The SEERS Hybrid hot water system works on a similar principal to the heat pump. However, the Seers system has the added advantage of highly efficient heat transfer. The SEERS hybrid system has all advantages of the heat pump, but overcomes the disadvantages for mechanically driven heat pump and solar powered systems.

12v DC Operated: Very low initial investment for wiring and reduced energy loading for the building, running on 2.4 to 4.5 amps.

Suitable for any building: Unlike solar systems, our modular system can fit into any building location such as roof attic, Air-conditioner ledge, basement, and even outdoors.

Suitable for any weather conditions:  The SEERS’s DC powered system works in any weather conditions even in extremely cold temperatures.

Guaranteed performance of hot water supply: Produces consistence hot water temperatures regardless of weather conditions. It even works all day and all through the night.

Finger-tip Programmable temperature control: Adjustable temperature control (up to 98C) offering a support data network through normal building management systems.

No heating elements: No heating element means no live contact with water. This ensures the system is 100% is safe. And, there is no need for a back up booster.

No Compressor: The Seers is a non-mechanical driven system that saves on maintenance and on mechanical parts like hermatic compressors and valves etc.

Size availability:  Available in 4 sizes (100L, 150L, 300L & 500L), the Seers is suitable for any application; residential, condominium, hotel, Spa, hospital and commercial. The modular system can even be installed in series and up-graded to meet your hot water requirements.

No Freon:  Ensures that the Seers system is 100% environmentally friendly.

  • 100% consistent of Hot water supply
  • Works day & night
  • No live wire connecting in your water tank
  • Temperature adjustable
  • Can be positioned any where
  • Can be re-located even if you move house
  • Absorbs heat from ambient air
  • Powered by 12 Volt DC
  • Releases cool air back to environment
  • No heating element or compressor
  • Programmable temperature control
  • Remote LCD display
  • Attractive exterior powder coated steel casing
  • Protected from overheating
  • Fault indicator
  • Temperature and pressure release valves
  • Magnesium anode rod
  • No need heavy roof-top equipment (Solar Panels can be above 500 kg)
  • No dangerous roof-top repairs
  • Not dependent on the sun
  • No live wire connection to water supply (No heating element)
  • No 20 Amps plug point
  • No legionnaires virus
  • Retains the external beauty of your house
  • No lightning strike worries
  • External circulation pump ON/OFF time control (Optional)

Seers Hot water System

  • 5 years all parts warranty (excluding labor & transport)
  • Adjustable temperature
  • Wire control panel
  • Good insulation
  • No heating element & No compressor
  • No worry of electrical shock
  • Maintenance Free
  • Low energy consumption
  • 100% hot water consistency
  • Modular system

Inconveniences of Solar water heater

  • Dependent on weather
  • Need Maintenance
  • High risk of roof damage during maintenance
  • Cause electrical Shock (heating element)
  • No temperature control
  • Heavy weight above 500kg per unit
  • Lighting strike worry
  • Legionnaires worry
  • Can't be position any where
  • Dangerous during roof top repairing

Inconveniences of Heat Pump System

  • Used 3 phase
  • Need services quarterly
  • Without service, compressor tend to breakdown, which is costly
  • Unable to adjust the temperature (max 55C)
  • Too hot water will damage/shorten compressor lifetime
  • Not green enough as it still use feon
  • Compressor too noisy
  • Calorifier tank need heating element
  • Expensive spare parts
  • Circulation pump needed to run from calorifier tank to compressor all time
  • Loss heat from calorifier tank
 
     
  Comparison Table  
 
  SEERS Heat Pump Solar Electric
Maintenance No regular services regular sevices with panel No
Freon No Yes No No
Climate below 15deg.C or 35deg.C 100% works. All weather Cannot work Depends on weather 100% works
Noise No Yes No No
Power Socket 13Amps 20-45Amps 20Amps 20-45Amps
Heating element (electric booster) No Yes Yes Yes
Power Input 480-1600 Watts   3000 Watts 3000-3800 Watts
C.O.P. 4.3. Any weather & temperature     0.8
Weight with water 145kg-630kg 250kg-800kg 500kg< 300kg<
Temperature (max) 98deg.C 50deg.C 50deg.C-100deg.C 70deg.C
Voltage 12 Volt D.C. 240-415 (3 phase) 240 V 240 V
Life Span 10-15 years 5-8 years 5-12 years 3-5 years
Safety Very safe Very safe Electrocution risk Electrocution risk
Operated in 4 season country Yes No Highly depended on weather Yes
Compressor No Yes No No
Amps 2.4 to 6Amps   10.8< 10.8<
Control panel Yes Yes No No
Create uneven pressure No No Yes No
 
     
     
  Comparison with various system in the market  
 
Type of Heater System

Source 
of Energy

Power 
Consumption

Lift Span

Productivity Levels

Safety

SEER Hybrid System

Air + Electricity

120(480) watt

10-12 Years

Continues supply of Hot Water day and night

Very Safe

*Solar heater System

Sunlight + Electricity

3000 watt

10-12 Years

Weather dependent

Safe

Storage Heater System

Electricity

3000 watt

5-6 Years

Slow hot water recovery

Safe

Instant Water Heater

Electricity

3000 watt

3-5 Years

Stand Alone System

Electrocution Risk

LPG Burner Heater

Liquefied Petroleum Gas

Nil

5-6 Years

Stand Alone System

Danger

*Solar Heater System with Electric Booster 

 

Cost Comparison with Solar Heater System

Type of Heater System

Usage per day

Usage of Power

Unit

Total usage of electricity per year

***Total in Value

SEER Hybrid System

200L @ 40'C

365 days

1.22

1.22 x 365 days = 445.3 units / kwh

114.49 per year

*Solar heater System

200L @ 40'C

**120 days

9.34

9.34 x 120 days = 1120.8 units / kwh

309.91 per year

*Solar Heater System with Electric Booster 

**Solar heater system based on 1/3 of the year requiring electric booster caused by weather and night usage.

***TNB Electricity charges first 200 units (0.218 / units), 200 units onward (0.289 / units

 

 
 
 
Copyright © 2009 SEERS INTERNATIONAL. All Right Reserved